Operative Techniques in Orthopaedic Surgery (4 Volume Set) 1st Edition

548. Anterior Lumbar Interbody Fusion, Disc Replacement, and Corpectomy

P. Justin Tortolani, Paul C. McAfee, and Matthew N. Scott-Young

DEFINITION

images Lumbar disc degeneration is an age-related process heralded by a loss of disc height and gradual changes to the biochemical structure and biomechanical behavior of the intervertebral disc.

images Disc degeneration is not painful in most individuals, but in some patients, the degenerative changes do become painful and lead to the clinical entity known as degenerative disc disease (DDD). It is unclear why disc degeneration is painful in some but not in most.

images The etiology of DDD is multifactorial, including genetic and environmental determinants.

images “Discogenic pain” is the term used to describe pain due to a degenerative disc.

ANATOMY

images The intervertebral disc is composed of the outer annulus fibrosus and the inner nucleus pulposus techfig 1A).

images The vertebral endplate is composed of cancellous bone in the center and strong, dense, cortical bone along the periphery.

images MRI provides information about the extent of hydration within the disc nucleus. The degenerated disc nucleus will have low signal characteristics (appear dark) on T2-weighted MRI images (fig 1B).

images Dark discs on MRI do not necessarily correlate with symptomatic low back pain.3

PATHOGENESIS

images Various mechanisms have been proposed to explain disc degeneration with age:

images Reduced nutrition and waste transport

images Decreased concentration of viable cells

images Loss of matrix proteins, proteoglycans, and water

images Degradative enzyme activity

images Fatigue failure of the matrix

images Herniated nucleus pulposus

images Alterations to the vertebral endplate microenvironment such as venous pooling and reduced oxygen tension are additional factors.

images Nicotine has known detrimental effects on the intervertebral disc, perhaps via these mechanisms.

images Several factors have been implicated in the generation of discogenic pain: altered disc structure and function, release of inflammatory cytokines, and nerve ingrowth into degenerated discs, which under normal conditions are only minimally innervated in the outermost portion of the annulus.

NATURAL HISTORY

images Radiographic findings of disc degeneration typically appear around age 30.

images Posttraumatic disc herniations, vertebral endplate injuries, and genetic factors may predispose patients to earlier presentation.

images As structural changes occur within the intervertebral disc, associated changes in the vertebral body endplate become apparent:

images Anterior, lateral, or posterior osteophyte formation

images Schmorl nodes, cystic cavities, along the endplate can be visualized

images Endplate sclerosis

images The degenerative changes at the level of the disc, bony endplate, and ultimately the posterior facet-joint complex ultimately restrict motion at the affected level or levels. At this stage, patients will typically complain more of back stiffness and soreness rather than pain. Neurogenic claudication due to narrowing of the spinal canal and spinal stenosis typically becomes more limiting than complaints of back pain.

images The final stage in the natural history of disc degeneration is autofusion.

images Patients should be counseled that disc degeneration itself is an inevitable process of aging and that any back pain experienced could, but may not necessarily, be associated with the disc degeneration.

images The overwhelming majority of patients have only occasional episodes of low back pain. Long-term disability resulting from DDD is rare.

PATIENT HISTORY AND PHYSICAL FINDINGS

images No pathognomonic history or physical examination findings exist for the diagnosis of lumbar DDD.

images Discogenic back pain is typically worst in situations in which an axial load is applied to the lumbar spine, as in prolonged sitting or standing with a forward-bent posture (ie, washing dishes, vacuuming, shaving, or brushing teeth).

images Conversely, positions such as side-lying (ie, the fetal position) or floating erect in water place the least amount of strain across the intervertebral disc and should therefore provide some pain relief.

images Leg pain (in the absence of neural compression), if present, is nonradicular and “referred” in that it does not follow lumbar dermatomes into the lower leg and is not typically associated with loss of motor power, reflex changes, numbness, or tingling.

images Patients will occasionally describe a discrete traumatic disc injury in which they first experienced back pain. Imaging studies that depict an old endplate fracture above or below a degenerative disc help corroborate this history.

images Loss of truncal musculature fitness from abdominal wall hernias, obesity, and prior abdominal wall surgery (ie, rectus muscle transfer procedures) may worsen discogenic back pain.

images

FIG 1  A. The intervertebral disc is composed of the outer annulus fibrosus (radial orientation of collagen fibers) and the inner nucleus pulposus (relatively higher water content and proteoglycans). The cancellous center of the lumbar vertebral body is surrounded by a peripheral rim of relatively strong cortical bone. B. T2-weighted sagittal MRI showing degenerative disc disease at the L4-5 disc space. The nucleus pulposus is low signal intensity (dark) compared to the adjacent discs, which are high signal intensity (bright) due to relatively higher water concentration. The vertebral body endplates are irregular, with anterior vertebral osteophytes.

images Other causes of back pain should be sought in the history, physical examination, and imaging studies, including muscular strain, spondylolysis or spondylolisthesis, herniated nucleus pulposus, compression fracture, pseudarthrosis, tumor, and discitis.

images Patients with isolated DDD by definition should have a normal neurologic examination.

IMAGING AND OTHER DIAGNOSTIC STUDIES

images Standing plain radiograph.

images Lateral radiographs allow for measurement of the intervertebral disc height and allow comparison to other lumbar intervertebral discs (fig 2A).

images Anteroposterior (AP) radiographs allow for determination of asymmetric, coronal plain disc degeneration, which may be a precursor to lumbar degenerative scoliosis.

images Flexion-extension radiographs may be helpful in diagnosing an occult spondylolisthesis or spondylolysis.

images MRI provides excellent visualization of the discs, the degree to which they have degenerated, and the relationship of the discs to the adjacent endplate and surrounding neurologic structures (fig 2B).

images Provocative discography attempts to reproduce the patient’s typical back pain by pressurizing the disc with normal saline. The patient needs to be awake to provide subjective feedback as to the quality and intensity of the pain. Architectural changes to the disc are inferred by contrast administered with the saline.

images CT discography provides more detailed information about the disc morphology after contrast administration (fig 2C).

images Normal laboratory tests, including complete blood count, erythrocyte sedimentation rate, and C-reactive protein, can help rule out a disc space infection; severe disc degeneration can sometimes mimic infection radiologically.

DIFFERENTIAL DIAGNOSIS

images DDD

images Discitis

images Pyogenic vertebral osteomyelitis

NONOPERATIVE MANAGEMENT

images DDD is analogous to hip and knee osteoarthritis in that the intervening cartilage (in the case of the disc: collagen, water, and proteoglycans) fails under compressive loads.

images Weight reduction and activity modification (avoidance of exacerbating activities) may be effective first-line treatments.

images Nonsteroidal anti-inflammatory medications

images Acupuncture or massage therapy

images Physical therapy with aquatic or dry land exercises

images Gentle pelvic traction

images Methylprednisolone (Solu-Medrol) taper

images Epidural injections

images Narcotic medications for severe episodes of pain

SURGICAL MANAGEMENT

images Indications

images Discogenic back pain refractory to nonoperative management

images Discitis with pyogenic vertebral osteomyelitis refractory to nonoperative management

images Spinal deformity requiring radical discectomy

images A thorough and complete discectomy improves the effectiveness of anterior interbody fusion by creating a wide surface area of exposed bone.

images

FIG 2  A. Lateral radiograph showing degenerative disc disease at the L2-3 level. B. Sagittal T2-weighted MRI of the same patient with low signal intensity in the nucleus of the L2-3 disc. Anterior and posterior disc bulges are present. C. Sagittal CT discogram of the same patient showing dramatic loss of integrity of the L2-3 nucleus and annulus with leakage of contrast anteriorly. The patient’s pain was concordant at the L2-3 disc level. The L1-2 and L3-4 discs served as negative controls with regard to both disc architecture and pain.

images Interbody reconstruction and fusion can be accomplished by a variety of methods, including structural autogenous bone graft (iliac crest or fibula), structural allograft (ie, femoral or humeral ring, femoral head, machined bone dowel), or synthetic device (titanium, PEEK, carbon-fiber, composite) packed with cancellous bone or collagen sponges impregnated with bone morphogenic protein 2 (BMP-2).

images Regardless of the method used, prerequisites are that the interbody spacer be strong enough to resist intervertebral compressive loads and provide an appropriate biologic environment for healing.

images The particular interbody fusion device of choice (eg, BagbyKuslich [BAK; Zimmer Spine, Warsaw, IN], lumbar-tapered [LT] cage [Medtronic Sofomor Danek, Memphis, TN], Bengal carbon fiber cages [DePuy Spine, Raynham, MA]) is inserted with instruments designed for proper implantation.

images BMP-2 has been approved by the U.S. Food and Drug Administration for anterior interbody application and has been shown to increase the fusion rate when compared to iliac crest bone graft.5

Preoperative Planning

images Plain radiographs, MRI, or CT scans should be carefully evaluated for undiagnosed spondylolysis or spondylolisthesis, which may alter the surgical plan.

images Templates can be used with plain radiographs or MRI scans to gauge the size of the final implant to be used.

images Oversized implants can lead to undesired stretch on neurologic structures and reduced motion of lumbar disc replacements.

images The level of the confluence of the common iliac veins into the inferior vena cava and the bifurcation of the aorta can be located on the axial MRI scans.

images At L5-S1 the pubic symphysis occasionally precludes appropriate visualization and instrumentation of the disc space in patients with a deep-seated L5-S1 relative to the pelvis. Evaluation of the lateral radiograph with the pubis on the film is critical to visualize the trajectory into the disc space and avoid this miscalculation.

Positioning

images See Chapter SP-4.

images The patient is placed over an inflatable pillow over a 1-inchthick foam pad, which is placed on the mattress of the operating table. The pillow allows for modulation of lordosis throughout the procedure and the foam pad props the patient up, allowing the arms to be tucked posteriorly, out of the plane of the spine during imaging.

images Positioning over the break in the table allows for increased lordosis if needed.

images The use of fluoroscopic C-arm imaging is crucial for appropriate patient and implant positioning. It is helpful to verify that adequate fluoroscopic imaging of operative landmarks can be achieved after the patient is positioned but before the incision is made.

Approach

images See Chapter SP-4 on anterior lumbar approach.

images Anterior retroperitoneal approaches will typically allow access to the lumbar discs from L2-3 to the sacrum.

images The renal vessels limit more proximal extension of the exposure.

images Lateral exposures to the lumbar spine are required for access to the L2 vertebra and above.

TECHNIQUES

ANTERIOR LUMBAR RADICAL DISCECTOMY

Exposure

images  Identify the intervertebral disc and mark the midline with a spinal needle or screw placed into the vertebral body (we prefer not to place a needle into the disc space because this may create unwanted disc injury) (TECH FIG 1A).

images  Use AP and lateral fluoroscopic imaging to check the midline. The midline marker also serves to verify the spinal level.

images  At L5-S1, retract the left common iliac artery and vein to the patient’s left and the right common iliac artery and vein to the right. At levels above L5-S1, the aorta and inferior vena cava must be mobilized to the patient’s right.

images  The great vessels can be held in their retracted position using handheld Hohmann retractors, custom-designed pins, or K-wires, all of which can be advanced directly into the vertebral bodies (virtually eliminating the risk of vessel migration into the field of interest) (TECH FIG 1B).

images Alternatively, stainless-steel vein retractors or radiolucent retractors can be fixed to the arms of an abdominal retractor system (Omni) or floating, Endo-ring-type retractor system. These blade retractors have the disadvantage of allowing vessel migration into the field by sliding under the retractor blades as motion occurs during the procedure. The advantage of the radiolucent retractors is that better visualization of the operative field is possible with fluoroscopy. In addition, blade-type retractors can be easily manipulated during the procedure without having to reinsert into the vertebral body.

images  Attempt to retract the vessels as far lateral as you can to allow for the widest possible view of the intervertebral disc. Poor visualization at this stage will compromise the quality of the discectomy and any ensuing interbody device placement.

Removing the Disc

images  Using a 10-blade on a long handle, incise the intervertebral disc starting laterally along the superior endplate and move toward midline. Always move away from the vessels to avoid an accidental lateral plunge into the great vessels. The blade should be inserted between the cartilage endplate and bone if possible, and we use both hands on the knife shank for optimal control and coordination (TECH FIG 2A,B).

images  A large, sharp Cobb elevator is then used to release as much of the cartilaginous endplate as possible from the superior and inferior endplates. By angling the Cobb blade toward the bone and pronating and supinating the hand, almost the entire disc (annulus and nucleus) can be removed, as if peeling an orange in one large piece (TECH FIG 2C).

images  Long-handled no. 2 and no. 3 Cobb curettes are used to remove the remaining disc, taking the dissection all the way to the posterior longitudinal ligament (TECH FIG 2D). Systematic removal of endplate cartilage enhances thorough removal. Thus, start anteriorly on the superior endplate and move posteriorly. Then start anteriorly on the inferior endplate and move posteriorly.

images The curette will function much more effectively if it is used as a cutting instrument rather than a scraper. For this reason, we prefer that curettes be sharp, nonangled, and used with a pronating–supinating motion with the edge of the curette between the cartilage endplate and the endplate bone.

images  The posterior longitudinal ligament is not routinely removed, but the posterolateral corners of the disc space must be thoroughly débrided of disc material for several reasons:

images Periphery of the endplate is the strongest bone and therefore provides the most stable support of an interbody device.

images Disc material that is left over can be pushed posteriorly into the epidural space, causing an iatrogenic disc herniation during implant insertion.

images If anterior decompression of the neural foramen is one of the goals of surgery, visualization and removal of a herniated disc or disc–osteophyte complex will not be possible without proper visualization in this region.

images

TECH FIG 1  A. Lateral radiograph showing the spinal needle inserted into the L4 vertebral body above the L4-5 disc to be removed. B. Lateral radiograph showing sharp Hohmann retractors placed into the L4 vertebral body above and L5 vertebral body below. Blade-type retractors can be left in place lateral to the Hohmann retractors for additional visibility, as shown.

images  The lateral extent of the discectomy is determined by the width of the device to be inserted, but care must be taken to maintain the width of the discectomy posteriorly as the natural tendency is to remove less disc laterally in the posterior portion of the disc space.

images  A lamina spreader can be gently distracted in the anterolateral interbody region to gain enhanced visibility of the posterior disc space (TECH FIG 2E).

images  Removal of a posterior or foraminal disc herniation can be accomplished by passing an angled Kerrison rongeur posteriorly and into the neuroforamen. Identification of the ventral aspect of the dura enhances the safety of this maneuver (TECH FIG 2F).

images  Epidural bleeding can be brisk during posterior disc removal, but thrombin-soaked Gelfoam gauze and removal of intervertebral distraction can be used to control it.

images

images

TECH FIG 2  A,B. Direction of movement of the surgical blade. At L5-S1 the surgical field is within the bifurcation of the great vessels, so the surgical knife should always be directed toward the midline and inferiorly—away from vascular structures. At L4-5 and above, the vascular structures are retracted to the patient’s right, and therefore movements with the knife blade are directed to the patient’s left and inferiorly. C. A large Cobb is used between the disc cartilage and the vertebral body to remove as much as possible in one large piece. D. Lateral radiograph showing a no. 2 Cobb curette used to remove the cartilaginous disc endplate. E. Lateral radiograph demonstrating a lamina spreader creating distraction within the disc space. The distractor enhances visualization of the posterior portion of the disc space. Care should be taken to make sure that the distractor is seated anteriorly and laterally on strong endplate bone to avoid damage to the central cancellous region. F. Lateral radiograph showing the use of a 4-mm-long Kerrison rongeur to decompress the neural foramen.

ANTERIOR LUMBAR INTERBODY FUSION

images  Once the discectomy has been completed, disc space distractors are inserted to gauge the size of the final implant (TECH FIG 3A). Appropriate distractor size can be gauged by comparing the operative level with a normal disc above or below. In addition, the interface between the distractor and the bony endplate should be less than 1 mm. This ensures good interference fit of the final device.

images  For threaded devices such as the LT cage, a cannulated guide channel is inserted over the disc distractors. This working channel serves to prevent inadvertent migration of the great vessels into the disc space.

images  Endplate reamers are then inserted to appropriate depth as determined by lateral fluoroscopic imaging (TECH FIG 3B). Care should be taken to aim the reamer for the midportion of the disc space posteriorly on lateral fluoroscopy rather than through one endplate or the other.

images Asymmetric reaming will result in excessive removal of one endplate compared to another and the final implant will be more likely to fail in subsidence. Because the reamer tends to follow the path of least resistance, an exceptionally sclerotic endplate will predispose one to asymmetric reaming by this mechanism.

images  Final threaded implants are then screwed into the appropriate depth and orientation (TECH FIG 3C,D). The first cage (in a dual-cage system) is inserted in the same trajectory as the reamers, and lateral fluoroscopic imaging during cage placement ensures that the cage is not placed too anteriorly or posteriorly. The cage should not be inserted beyond the depth of the reamer or else the threads will strip and the cage will lose a large percentage of its fixation strength.

images

images

TECH FIG 3  A. Lateral radiograph showing a radiopaque disc distractor within the intervertebral disc. The distractor approximates the height of the disc space above (L3-4), and there is at most 1 mm of space between the intervertebral endplate and the distractor. B. Lateral radiograph showing reaming of the intervertebral channel for the anterior interbody device. Because the vertebral body is shallower in the AP plane away from the midline, reaming should stop shy of the posterior vertebral body line, as shown. C. Lateral radiograph showing threaded cage entry into the disc space. The cage is directed parallel to the vertebral endplates. D. Final cage placement should not extend beyond the depth of the reamer. E. Lateral radiograph showing final cage placement. The overlapping pedicles confirm true lateral positioning. F. AP radiograph showing parallel positioning of paired cages.

images Saving the C-arm image of the final reamer depth allows the surgeon to reference this image when inserting the cage.

images  The second cage is inserted using the first cage as a reference for trajectory and depth. Final images should be true AP and lateral projections showing the cage devices to be in good position. Overlapping pedicles on the lateral image will appear sharp, confirming true lateral positioning (TECH FIG 3E,F).

LUMBAR TOTAL DISC REPLACEMENT

Determining Implant Size

images  Determine midline and the appropriate spinal level by inserting a bone screw, which will serve as a reference throughout the case. Obtaining true AP and lateral images is critical to ensure that the remainder of the instruments and devices can be referenced off these radiographic landmarks (TECH FIG 4A).

images  Once the discectomy is completed, a sizing guide, or “lollipop,” is used to ascertain the size of the implant to be used (TECH FIG 4B). These guides vary in depth and width to conform to the size of the vertebral endplate. The endplate of S1 is often more shallow in the AP dimension than L5, and this may necessitate the use of a smaller implant at this level.

images  The largest footprint that is still covered by the vertebra is chosen. This helps to ensure that the final device will be supported by the greatest percentage of peripheral cortical bone.

images  The height and lordosis of the final implant are determined by trial wedges that fit into the interbody location (TECH FIG 4CE). The vertebral endplates should be flush with the trials.

images

TECH FIG 4  A. True AP fluoroscopic image. The distance between the midpoint of the vertebra and the pedicles should be the same. The cortical margins of the pedicles themselves should be the same size (ensuring the spine is not rotated). Finally, the spinous processes should bisect the vertebra. The spinous processes are the least reliable landmark, as they can be malformed, especially at L5 and S1. B. A sizing guide, or “lollipop,” demonstrates how well the endplate will be covered by the final implant. The largest size that allows good peripheral endplate coverage in both the sagittal and coronal planes is desired. C–E. Using radiolucent trial wedges of varying height and lordosis allows the final device to be individualized to the patient’s anatomy. (B–E: Courtesy of DePuy Spine, Raynham, MA.)

images

TECH FIG 5  A. Intraoperative photograph showing introduction of the channel cutter into the disc space. B. Care is taken to ensure that the cutting channels are centered on the midline marking screw and are directed straight posterior. C. Intraoperative photograph showing prosthesis insertion into the grooves created by the channel cutter. D. Lateral fluoroscopic image showing implant insertion. The insertion instruments are still connected, which allows for fine adjustment to the final positioning. E,F. Lateral and AP fluoroscopic images of the final TDR placement with all of the instruments removed. The final implant should be in the center of the vertebral body on the AP image and in the center (sagittal midline) or just posterior to the center of the vertebral body on the lateral image.

Implant Placement

images  Grooves for a central keel or for fixation teeth are then cut. Make sure the central groove is in the midline and that the trajectory for the grooves is directly posterior and not angled (TECH FIG 5A,B).

images  The final implant is then inserted (TECH FIG 5C,D). Double-check that the implant is the correct size and is inserted in the correct orientation regarding lordosis.

images  It can be helpful to break the bed or inflate the lumbar pillow to get the disc implant started in a particularly collapsed disc. Once the implant is halfway into the disc space, the lordosis should be removed so that the implant will move easily into the posterior portion of the disc (TECH FIG 5E,F).

ANTERIOR LUMBAR CORPECTOMY

Vertebra Removal

images  The indications for anterior corpectomy in the lumbar spine are lumbar burst fracture, catastrophic failure of lumbar disc replacement or interbody device (ie, vertebral fracture), lumbar vertebral osteomyelitis, correction of kyphosis, and vertebral body malignancy.

images In cases of corpectomy for vascular tumors, preoperative embolization should be performed (TECH FIG 6A).

images In cases of corpectomy, lumbar radical discectomies are performed above and below the vertebral body to be removed (see discectomy technique above).

images

TECH FIG 6  A. Pre-embolization angiogram depicting the aortic bifurcation in a 65-year-old patient with metastatic renal cell carcinoma to the L4 vertebra. Note the degree of vascularity of the L4 vertebral body. B.Postembolization angiogram depicting a striking reduction in contrast entering the L4 vertebral body. Small embolization coils are seen in the vascular network surrounding the vertebral body. C. Anterior discectomy enables the surgeon to use a large rongeur to gain access to the edge of the vertebra and thereby remove the vertebral body bone.

images This enables the surgeon to become oriented to the midline and also to judge the depth and width of the corpectomy to be performed.

images The discectomy space also allows the surgeon to use a large rongeur efficiently to remove the vertebral body (TECH FIG 6B).

images  Retractors should be placed above and below the entire vertebra to be removed so there is an unobstructed view for the surgeon and the assistants. The vertebral body bleeds more rapidly than the endplates, so the assistants need to be able to visualize the operative field to suction effectively.

images  A Leksell rongeur can be used to remove all of the vertebral body back to the level of the posterior cortex. If this needs to be removed, angled curettes are used to develop the plane behind the vertebra, starting at the disc space. Kerrison punches or angled curettes are then used to lift the posterior cortex off the ventral dura.

images Healthy vertebral body bone should be saved for interbody fusion.

Filling the Interbody Space

images  Once the corpectomy is completed, bone graft or an interbody device is contoured to fit into the defect. The wooden end of a cotton-tipped applicator can be cut to the length of the defect and can then be used as a size gauge for the final interbody device. This is particularly useful when cutting and contouring a bone graft beca use calipers and rulers do not always fit easily into the central portion of the corpectomy defect to give an accurate height measurement.

images  Check the height of the corpectomy defect with the wooden applicator throughout its entire depth, from anterior to posterior. Keep in mind that the shape of the corpectomy site may be lordotic, and thus the bone graft or implant needs to be fashioned appropriately.

images  Allograft strut grafts such as femoral head, humerus, or femoral shafts can be cut using an oscillating saw to fit snugly into the interbody space. The advantages of allograft are it can be packed with morselized autogenous bone, it has a similar modulus of elasticity to host vertebral bone, and it will become osseointegrated over time.

images  Autogenous tricortical iliac crest and autogenous fibula have the greatest healing potential but are also associated with significant harvest site morbidity.

images  Metal cages generally are the easiest to fashion to fit the corpectomy space and can be packed with morselized corpectomy bone (TECH FIG 7A). The disadvantages are their expense and relatively reduced surface area at the endplate for fusion compared to bone.

images  The width of the corpectomy should be kept as narrow as possible without compromising decompression or removal of pathologic bone (TECH FIG 7B).

images Allows bone ingrowth from the corpectomized vertebral body into the interbody bone graf.

images Enhances the stability of the interbody strut

images  A bone screw with a washer can be used above and below large defects as an “anti-kickout” buttress for allografts (TECH FIG 7C).

images

TECH FIG 7  A,B. AP and lateral postoperative radiographs of a patient in whom posterior element resection followed by fusion and instrumentation with pedicle screws was performed as a first stage, followed by complete anterior corpectomy and reconstruction with a cylindrical titanium mesh cage packed with autogenous bone graft. An anterior side plate was applied as the lateral vertebral body wall was completely removed. C. The corpectomy strut device should fit snugly against the cut edge of the vertebral body to promote side-to-side fusion from host bone to strut graft. D. Intraoperative image of anterior allograft reconstruction after corpectomy, irrigation, and débridement of the L3 vertebra in a 62-year-old man with L3 vertebral body destruction from pyogenic vertebral osteomyelitis. 4.5-mm cortical screws with washers are used to prevent allograft kickout.

images

images

FIG 3  Sagittal fine-cut CT image depicting trabecular bone bridging across the disc space 3 months after anterior interbody fusion with a threaded titanium cage packed with collagen sponges impregnated with bone morphogenic protein 2.

POSTOPERATIVE CARE

images As soon as the patient emerges from anesthesia, a complete neurologic examination and brief history should be performed. Specifically, patients should be asked if they have any new leg pain. If present, CT myelography or plain CT scans should be obtained to ensure that no bone, disc material, or portion of an implanted device is impinging on the lumbar nerve roots.

images Nasogastric tubes for the first 12 to 24 hours help to minimize abdominal wall distention and postoperative ileus.

images Patients are encouraged to walk on postoperative day 1.

images Lumbar corsets or abdominal binders are prescribed at the discretion of the surgeon and may reduce the tension on the abdominal incision in the early postoperative period.

images Return to heavy manual labor is restricted in patients undergoing anterior interbody fusion until the fusion is solid. Fine-cut CT scans are useful in documenting solid fusion if there is doubt on AP, lateral, or flexion-extension radiographs (fig 3).

images Manual labor should be restricted in patients undergoing disc replacement until the bone–prosthesis interface is judged to be stable. In nonkeeled total disc replacement devices requiring porous ingrowth for definitive fixation, such as the Charite (DePuy Spine, Raynham, MA), at least weeks out of work is recommended.

OUTCOMES

images Level IV evidence reported by Tropiano et al showed significant improvements in back pain, radiculopathy, and disability at mean of 8.7 years after insertion of the Prodisc lumbar disc replacement.10

images Anterior lumbar interbody fusion with titanium cages and iliac crest bone graft has been shown to yield significantly greater fusion rates (97%) versus allograft dowels packed with iliac crest bone graft (48%).8

images Patients undergoing anterior lumbar fusion with the titanium cages packed with BMP-2-impregnated collagen sponges have significantly improved fusion rates and clinical outcomes compared to patients in whom the cages were packed with iliac crest bone graft.5

images In a prospective, randomized trial comparing Charite lumbar disc replacement to stand-alone anterior lumbar interbody fusion with titanium cages and iliac crest bone graft (control group), a significantly greater percentage of patients undergoing disc replacement were satisfied with their procedure versus the control group at 2-year follow-up.

images Hospital stay was significantly shorter in the disc replacement group compared to controls.

images However, at 2 years there was no statistical difference between the disc replacement group and the control group with respect to pain or disability.2

images Clinical outcomes and flexion-extension range of motion correlate with surgical technical accuracy of lumbar disc replacement.6

COMPLICATIONS

images Most complications associated with anterior lumbar discectomy, interbody fusion, disc replacement, and corpectomy are approach-related1,2,4,7,10 (see Chap. SP-4).

images The most common complications of anterior lumbar interbody fusion are pseudarthrosis and device failures such as migration or breakage.

images The complications of lumbar disc replacement depend on the exact type of device being inserted but generally can be categorized as follows:9,11

images Device failures: metal endplate breakage, core dislodgement or fracture, polyethylene degradation

images Bone-implant failures: subsidence, vertebral body fracture, implant migration or dislocation

images Iatrogenic deformity: kyphosis, scoliosis

images Host response: osteolysis, heterotopic ossification

images Infection

images Revision approaches to the anterior lumbar spine carry six times the risk of major bleeding or thromboembolic complications.7 Preoperative intravenous filter insertion, ureteral stenting, and percutaneous venous access wires are critical to reduce these risks.

REFERENCES

1.     Bertagnolli R, Zigler J, Karg A, et al. Complications and strategies for revision surgery in total disc replacement. Orthop Clin North Am 2005;36:389–395.

2.     Blumenthal SL, McAfee PC, Guyer RD, et al. A prospective, randomized, multi-center FDA IDE study of lumbar total disc replacement with the CHARITE™ Artificial Disc vs. lumbar fusion: part I: evaluation of clinical outcomes. Spine 2005;30:1565–1575.

3.     Boden SD, McCowin PR, Dina TS, et al. Abnormal magnetic resonance scans of the lumbar spine in asymptomatic subjects: a prospective investigation. J Bone Joint Surg Am 1990;72A:403–408.

4.     Brau SA, Delamarter RB, Schiffman ML, et al. Vascular injury during anterior lumbar surgery. Spine J 2004;4:409–412.

5.     Burkus JK, Heim SE, Gornet MF et al. Is INFUSE bone graft superior to autograft bone? An integrated analysis of clinical trials using the LT-CAGE lumbar tapered fusion device. J Spinal Disord Tech 2003; 16:113–122.

6.     McAfee PC, Cunningham BW, Holtsapple G, et al. A prospective, randomized, multi-center FDA IDE study of lumbar total disc replacement with the CHARITE™ Artificial Disc vs. lumbar fusion: part II: evaluation of radiographic outcomes and correlation of surgical technique accuracy with clinical outcomes. Spine 2005;30: 1576–1583.

7.     McAfee PC, Geisler FH, Saiedy SS, et al. Revisability of the CHARITE Artificial Disc Replacement: analysis of 688 patients enrolled in the U.S. IDE study of the CHARITE Artificial Disc. Spine 2006;31:1217–1226.

8.     Sasso RC, Kitchel SH, Dawson EG. A prospective, randomized controlled clinical trial of anterior lumbar interbody fusion using a titanium cylindrical threaded fusion device. Spine 2004;29: 113–122.

9.     Tortolani PJ, McAfee PC, Saiedy S. Failures of lumbar disc replacement. Semin Spine Surg 2006;18:78–86.

10. Tropiano P, Huang RC, Girardi FP, et al. Lumbar disc replacement: seven to eleven year follow-up. J Bone Joint Surg Am 2005;87A: 490–496.

11. van Ooij A, Oner FC, Verbout AJ. Complications of artificial disc replacement: a report of 27 patients with the SB CHARITE disc. J Spinal Disord Tech 2003;16:369–383.



If you find an error or have any questions, please email us at admin@doctorlib.info. Thank you!